3a

Diluent Heater Convection Coil Elbow.  High Temperature Failures - The Thermal-Stress Analysis of Leak Containment Thermal-Mechanical Stress Analysis of Device Installed on Diluent Heater Convection Coil elbow that had developed erosion / corrosion thinning.

3b

Hydrogen Reformer Radiant Coil Dissimilar Weld Failure. The Thermal-Stress Analysis of Hydrogen Reformer Process Gas Coil that had developed circumferential cracks in the HAZ zone of the butt welds between the coil tube and the stub pipe connecting the header.

3c

Steam Reformer Catalyst Tube. Overheating Thermal Bowing Failure - Thermal Creep Simulation and Elastic Creep Rupture Stress Analysis

CAESER Model

Steam Reformer Outlet Pigtails Piping. High Temperature Service Stress Flexibility - Thermal Creep Simulation and Elastic  Creep Rupture Stress Analysis

Home   Pressure Vessels Failure Analysis   Heat Exchangers Failure Analysis   Fired Heaters Failure Analysis   API Crude Natural Gas Storage Tanks - Failures   Chemical Plant Refinery Process Piping Systems Pipelines - Failures   Flanged Joints Gaskets Bolts of Piping - Leakage Failures in Service   Assessments   Contact Us